Central Battery Cubicles for Emergency Lighting Systems

Powerfaze central battery systems are manufactured to the highest standards to provide long, trouble-free service and can be specified with a range of battery types. The cubicles are manufactured from sheet steel and use lockable, lift-off covers, which provide excellent access to both charger and battery compartments during installation and maintenance.

A choice of load capacities in non-maintained, AC/DC maintained and floating DC/DC maintained systems are available in 24, 50, 100 Volts.

Ordering Codes & Information
Maintained Models
Non-Maintained Models
Voltage
Duration
Watts
Cabinet
PWF24/M3/420/AV/LV/S
PWF24/NM3/420/AV/LV/S
24V
3 Hours
420
1/A
PWF24/M3/545/AV/LV/S
PWF24/NM3/545/AV/LV/S
24V
3 Hours
545
1/B
PWF24/M3/635/AV/LV/S
PWF24/NM3/635/AV/LV/S
24V
3 Hours
635
1/B
PWF24/M3/780/AV/LV/S
PWF24/NM3/780/AV/LV/S
24V
3 Hours
780
1/C
PWF50/M3/270/AV/LV/S
PWF50/NM3/270/AV/LV/S
50V
3 Hours
270
1/A
PWF50/M3/380/AV/LV/S
PWF50/NM3/380/AV/LV/S
50V
3 Hours
380
1/A
PWF50/M3/600/AV/LV/S
PWF50/NM3/600/AV/LV/S
50V
3 Hours
600
1/A
PWF50/M3/840/AV/LV/S
PWF50/NM3/840/AV/LV/S
50V
3 Hours
840
1/C
PWF50/M3/1090/AV/LV/S
PWF50/NM3/1090/AV/LV/S
50V
3 Hours
1090
2
PWF50/M3/1270/AV/LV/S
PWF50/NM3/1270/AV/LV/S
50V
3 Hours
1270
2
PWF50/M3/1560/AV/LV/S
PWF50/NM3/1560/AV/LV/S
50V
3 Hours
1560
2
PWF50/M3/1960/AV/LV/S
PWF50/NM3/1960/AV/LV/S
50V
3 Hours
1960
3
PWF110/M3/610/AV/LV/S
PWF110/NM3/610/AV/LV/S
110V
3 Hours
610
2/C
PWF110/M3/870/AV/LV/S
PWF110/NM3/870/AV/LV/S
110V
3 Hours
870
2/C
PWF110/M3/1350/AV/LV/S
PWF110/NM3/1350/AV/LV/S
110V
3 Hours
1350
2/C
PWF110/M3/1900/AV/LV/S
PWF110/NM3/1900/AV/LV/S
110V
3 Hours
1900
3
PWF110/M3/2450/AV/LV/S
PWF110/NM3/2450/AV/LV/S
110V
3 Hours
2450
3
PWF110/M3/2850/AV/LV/S
PWF110/NM3/2850/AV/LV/S
110V
3 Hours
2850
4
PWF110/M3/3500/AV/LV/S
PWF110/NM3/3500/AV/LV/S
110V
3 Hours
3500
4
Options:
Replace # with quantity of outputs required.
/BS BS764 Contactor; /LVD Low Voltage Disconnect; /CA Common Alarm Relay (V/F Contact); DM Digital Ammeter/Voltimeter; /EF Earth Fault Monitor; /ET Engineers Test Key; /FA Fire Alarm Relay; /HL High/Low Volts Monitor; /MI MCB on Mains Input (Single Pole); /MM MCB on Maintained Circuit (Single Pole); /MR1 Maintained Control Relay (Max 1500 Watts); /MR2 Maintained Control Relay (Max 3500 Watts); /NW1 Night Watchman's Switch (Max 1500 Watts); /NW2 Night Watchman's Switch (Max 3500 Watts); /PF Phase Failure Relays; /TS Solar Dial Time Switch; /RA Remote Alarm Unit; /SR Sub-Circuit Relay; /FPL Flat Plate Lead Acid Batteries; /PLA Planté Lead Acid Batteries; /NCA Nickel Cadmium Alkaline Batteries; /#XD1 Double-Pole Fused Output (Max 32 Amps); /#XD2 Double-Pole Fused Output (Max 63 Amps).
Specification
Input Voltage
220/240 Volts 50Hz single phase or 380/415 Volts 50Hz three phase with phase failure detection relays fitted.
 
Output
24 Volts, 50 Volts or 110 Volts
 
Charger
Thyristor controlled constant Voltage type with electronic current limit and optional boost facility. Protected against short circuit, low battery Voltage and also reverse battery connection.
 
Meters
Moving coil charge Ammeter and battery Voltmeter.
 
Indicators
Mains healthy neon and charge fail LED.
 
Protection
HRC fuses to the input, charger and output. Low Voltage disconnect on sealed lead acid type batteries.
 
Enclosure
Sheet steel finished in grey RAL-7032
 
Recharge Time
Charges are rated to give 80% recharge within 14 hours and full recharge within 24 hours.
 
Minimum Battery Voltage
The battery Voltage at the end of a rated discharge shall not be less than 85% of the nominal system Voltage as defined in BS5266.
 
Fuses
Industrial HRC complying with the general requirements of BS88 Part 2; 1975.
 
Contactors
To the relevant requirements of BS5424 as standard but BS764 types available on request.
 
Transformers
Double wound with either bobbin or earth screen, complying generally with the requirements BS171.
 
Health & Safety
When lead acid and Nickel Cadmium wet cells are charged, they emit a potentially explosive mixture of Oxygen and Hydrogen. Adequate ventilation when installing equipment in confined areas is essential. A battery is electrically live at all times and can not be isolated in the conventional sense. Therefore, precautions restricting unauthorised access to battery rooms and cabinets should be undertaken.
Battery Options
Powerfaze central battery units are supplied with 10 year life sealed lead acid batteries as standard. Descriptions of battery options offering a variety of costs, service life and maintenance required are detailed as follows:
10 Year Life Sealed Lead Acid
Valve regulated lead acid batteries are the most popular choice for central battery systems as they are maintenance-free and have an expected service life of 10 years. The interior construction immobilises the acid within a sponge like material and the electrolyte remains throughout the charge and discharge cycles. There is no loss through gassing during the life of the battery as the cells are completely sealed.
 
Flat Plate Lead Acid
Low antimony pasted plated cells are housed within a translucent plastic case, which ensures ease of checking electrolyte levels. The cells have a low internal resistance, which result in good regulation, especially at higher rates of discharge. A large electrolyte reservoir enables longer periods between topping up. This type of cell has a reasonable tolerance to neglect and has a service life between 12 and 15 years.
 
Planté Lead Acid
There high performance cells offer ultra reliable trouble-free service when well maintained. The clear cell casing enable the electrolyte levels to be checked easily and a large electrolyte reservoir limits maintenance requirements. The cells retain 100% capacity throughout their design life and give excellent performance at high or low levels of discharge. This type of cell has a service life up to 25 years.
 
Nickel Cadmium Alkaline
These cells are extremely robust and will tolerate arduous operating conditions. The cells have translucent cases to enable the electrolyte level to be checked easily. Deep discharge has no adverse effect on the cell capacity and unlike lead acid cells, they can be left in a discharged condition without incurring damage. This type of cell has a service life up to 25 years.